Three-phase DSU WV 85-630 kVA Welland Power WV85, WV100, WV130, etc.
- Three-phase diesel generator WV85 - Engine model: TD520GE, power: Standby 93.5kVA - 74.8kW, Prime Power 85kVA - 68kW, fuel consumption (75% load): 14.5 l/hour.
- Three-phase diesel generator WV100 - Engine model: TAD531GE, power: Standby 110kVA - 88kW, Prime Power 100kVA - 80kW, fuel consumption (75% load): 17.9 liters/hour.
- Three-phase diesel generator WV130 - Engine model: TAD532GE, power: Standby 143kVA - 114KW, Prime Power 130kVA - 104KW, fuel consumption (75% load): 21.8 liters/hour.
- Three-phase diesel generator WV150 - Engine model: TAD731GE, power: Standby 165kVA - 132kW, Prime Power 150kVA - 120kW, fuel consumption (75% load): 26.6 liters/hour.
- Three-phase diesel generator WV175 - Engine model: TAD732GE, power: Standby 192.5kVA - 154KW, Prime Power 175kVA - 140kW, fuel consumption (75% load): 31.4 liters/hour.
- Three-phase diesel generator WV200 - Engine model: TAD733GE, power: Standby 220kVA - 176KW, Prime Power 200kVA - 160kW, fuel consumption (75% load): 34.6 liters/hour.
- Three-phase diesel generator WV250 - Engine model: TAD734GE, power: Standby 250kVA - 220kW, Prime Power 250kVA - 200kW, fuel consumption (75% load): 43.6 liters/hour.
- Three-phase diesel generator WV275 - Engine model: TAD940GE, power: Standby 302kVA - 242KW, Prime Power 275kVA - 220kW, fuel consumption (75% load): 44.5 l/hour.
- Three-phase diesel generator WV325 - Engine model: TAD941GE, power: Standby 357.5kVA - 286KW, Prime Power 325kVA - 260kW, fuel consumption (75% load): 52.7 l/hour.
- Three-phase diesel generator WV350 - Engine model: TAD1240GE, power: Standby 385kVA - 308KW, Prime Power 350kVA - 280kW, fuel consumption (75% load): 54.3 liters/hour.
- Three-phase diesel generator WV375 - Engine model: TAD1241GE, power: Standby 412.5kVA - 330kW, Prime Power 375kVA - 300kW, fuel consumption (75% load): 58.7 l/hour.
- Three-phase diesel generator WV400 - Engine model: TAD1242GE, power: Standby 440kVA - 352KW, Prime Power 400kVA - 320kW, fuel consumption (75% load): 64.2 liters/hour.
- Three-phase diesel generator WV460 - Engine model: TAD1640GE, power: Standby 506kVA - 404.8kW, Prime Power 460kVA - 368KW, fuel consumption (75% load): 70.9 l/hour.
- Three-phase diesel generator WV500 - Engine model: TAD1641GE, power: Standby 550kVA - 440kW, Prime Power 500kVA - 400kW, fuel consumption (75% load): 77.2 liters/hour.
- Three-phase diesel generator WV570 - Engine model: TAD1642GE, power: Standby 627kVA - 501.6kW, Prime Power 570kVA - 456KW, fuel consumption (75% load): 87.2 liters/hour.
- Three-phase diesel generator WV630 - Engine model: TWD1643GE, power: Standby 693kVA - 554.4kW, Prime Power 630kVA - 504KW, fuel consumption (75% load): 96.8 liters/hour.
All Welland Power products
The group «New Technologies» offers products from the plant Welland Power: gas-piston, diesel power plants, diesel generator sets, Welland Power noise protection shrouds
About Welland Power
Welland Power plants have more than 60 years of impeccable reputation. Welland Power offers a product range from 9 to 2000 kVA for all your energy needs, in full compliance with international quality and environmental standards.
-
INTERNATIONAL STANDARDS
All Welland Power plants are designed, developed and manufactured within the requirements of the UNI EN ISO 9001:00 (Vision 2000) and UNI EN ISO 14001:04 standards. -
GLOBAL BRANDS
Welland Power diesel power plants are produced exclusively from original components recognized on the international market for their quality: Perkins, Volvo Penta, Cummins, Mecc Alte, Newage Stamford. -
FOREIGN PRODUCTION
The Welland Power diesel generator was produced and is being produced only on the territory of the United Kingdom of Great Britain. The company's plant is located in the county of South Lincolnshire, 160 km from London.
- (727)345-47-04
- (3955)60-70-56
- (8182)63-90-72
- (8512)99-46-04
- (3852)73-04-60
- (4722)40-23-64
- (4162)22-76-07
- (4832)59-03-52
- (8352)28-53-07
- (351)202-03-61
- (8202)49-02-64
- (3022)38-34-83
- (395)279-98-46
- (4932)77-34-06
- (3412)26-03-58
- (4012)72-03-81
- (4842)92-23-67
- (843)206-01-48
- (3842)65-04-62
- (4212)92-98-04
- (8332)68-02-04
- (4966)23-41-49
- (4942)77-07-48
- (861)203-40-90
- (391)204-63-61
- (3522)50-90-47
- (4712)77-13-04
- (4742)52-20-81
- (3519)55-03-13
- (495)268-04-70
- (8152)59-64-93
- (8552)20-53-41
- (831)429-08-12
- (3843)20-46-81
- (383)227-86-73
- (3496)41-32-12
- (3812)21-46-40
- (4862)44-53-42
- (3532)37-68-04
- (8412)22-31-16
- (342)205-81-47
- (8142)55-98-37
- (8112)59-10-37
- (863)308-18-15
- (4912)46-61-64
- (812)309-46-40
- (846)206-03-16
- (8342)22-96-24
- (845)249-38-78
- (8692)22-31-93
- (3652)67-13-56
- (4812)29-41-54
- (862)225-72-31
- (8652)20-65-13
- (3462)77-98-35
- (8212)25-95-17
- (4752)50-40-97
- (8482)63-91-07
- (3822)98-41-53
- (4872)33-79-87
- (4822)63-31-35
- (3452)66-21-18
- (347)229-48-12
- (3012)59-97-51
- (8422)24-23-59
- (8672)28-90-48
- (4922)49-43-18
- (423)249-28-31
- (844)278-03-48
- (8172)26-41-59
- (473)204-51-73
- (4112)23-90-97
- (4852)69-52-93
- (343)384-55-89