Three-phase DSU WV 85-630 kVA Welland Power WV85, WV100, WV130, etc.
Three-phase diesel generator (DGU) WV85 - Engine model: TD520GE, power: Standby 93.5kVA - 74.8kW, Prime Power 85kVA - 68kW, fuel consumption (75% load): 14.5 liters/hour.
Three-phase diesel generator (DGU) WV100 - Engine model: TAD531GE, power: Standby 110kVA - 88kW, Prime Power 100kVA - 80kW, fuel consumption (75% load): 17.9 liters/hour.
Three-phase diesel generator (DGU) WV130 - Engine model: TAD532GE, power: Standby 143kVA - 114KW, Prime Power 130kVA - 104KW, fuel consumption (75% load): 21.8 liters/hour.
Three-phase diesel generator (DGU) WV150 - Engine model: TAD731GE, power: Standby 165kVA - 132kW, Prime Power 150kVA - 120kW, fuel consumption (75% load): 26.6 liters/hour.
Three-phase diesel generator (DGU) WV175 - Engine model: TAD732GE, power: Standby 192.5kVA - 154KW, Prime Power 175kVA - 140kW, fuel consumption (75% load): 31.4 liters/hour.
Three-phase diesel generator (DGU) WV200 - Engine model: TAD733GE, power: Standby 220kVA - 176KW, Prime Power 200kVA - 160kW, fuel consumption (75% load): 34.6 liters/hour.
Three-phase diesel generator (DGU) WV250 - Engine model: TAD734GE, power: Standby 250kVA - 220kW, Prime Power 250kVA - 200kW, fuel consumption (75% load): 43.6 liters/hour.
Three-phase diesel generator (DGU) WV275 - Engine model: TAD940GE, power: Standby 302kVA - 242KW, Prime Power 275kVA - 220kW, fuel consumption (75% load): 44.5 liters/hour.
Three-phase diesel generator (DGU) WV325 - Engine model: TAD941GE, power: Standby 357.5kVA - 286KW, Prime Power 325kVA - 260kW, fuel consumption (75% load): 52.7 liters/hour.
Three-phase diesel generator (DGU) WV350 - Engine model: TAD1240GE, power: Standby 385kVA - 308KW, Prime Power 350kVA - 280kW, fuel consumption (75% load): 54.3 liters/hour.
Three-phase diesel generator (DGU) WV375 - Engine model: TAD1241GE, power: Standby 412.5kVA - 330kW, Prime Power 375kVA - 300kW, fuel consumption (75% load): 58.7 liters/hour.
Three-phase diesel generator (DGU) WV400 - Engine model: TAD1242GE, power: Standby 440kVA - 352KW, Prime Power 400kVA - 320kW, fuel consumption (75% load): 64.2 liters/hour.
Three-phase diesel generator (DGU) WV460 - Engine model: TAD1640GE, Power: Standby 506kVA - 404.8kW, Prime Power 460kVA - 368KW, Fuel consumption (75% load): 70.9 liters/hour.
Three-phase diesel generator (DGU) WV500 - Engine model: TAD1641GE, power: Standby 550kVA - 440kW, Prime Power 500kVA - 400kW, fuel consumption (75% load): 77.2 liters/hour.
Three-phase diesel generator (DGU) WV570 - Engine model: TAD1642GE, power: Standby 627kVA - 501.6kW, Prime Power 570kVA - 456KW, fuel consumption (75% load): 87.2 liters/hour.
Three-phase diesel generator (DGU) WV630 - Engine model: TWD1643GE, power: Standby 693kVA - 554.4kW, Prime Power 630kVA - 504KW, fuel consumption (75% load): 96.8 liters/hour.
- WV85. Технические характеристики.
- WV100. Технические характеристики.
- WV130. Технические характеристики.
- WV150. Технические характеристики.
- WV175. Технические характеристики.
- WV200. Технические характеристики.
- WV250. Технические характеристики.
- WV275. Технические характеристики.
- WV325. Технические характеристики.
- WV350. Технические характеристики.
- WV375. Технические характеристики.
- WV400. Технические характеристики.
- WV460. Технические характеристики.
- WV500. Технические характеристики.
- WV570. Технические характеристики.
- WV630. Технические характеристики.
All Welland Power products
About Welland Power
-
INTERNATIONAL STANDARDS
All Welland Power plants are designed, developed and manufactured within the requirements of the UNI EN ISO 9001:00 (Vision 2000) and UNI EN ISO 14001:04 standards. -
GLOBAL BRANDS
Welland Power diesel power plants are produced exclusively from original components recognized on the international market for their quality: Perkins, Volvo Penta, Cummins, Mecc Alte, Newage Stamford. -
FOREIGN PRODUCTION
The Welland Power diesel generator was produced and is being produced only on the territory of the United Kingdom of Great Britain. The company's plant is located in the county of South Lincolnshire, 160 km from London.
NEW TECHNOLOGIES GROUP
Contact us or your local dealer for more information on certifications, features, reviews, pricing, stock availability and delivery terms for Welland Power products.
Reply guaranteed within 8 business hours
- (727)345-47-04
- (3955)60-70-56
- (8182)63-90-72
- (8512)99-46-04
- (3852)73-04-60
- (4722)40-23-64
- (4162)22-76-07
- (4832)59-03-52
- (8352)28-53-07
- (351)202-03-61
- (8202)49-02-64
- (3022)38-34-83
- (395)279-98-46
- (4932)77-34-06
- (3412)26-03-58
- (4012)72-03-81
- (4842)92-23-67
- (843)206-01-48
- (3842)65-04-62
- (4212)92-98-04
- (8332)68-02-04
- (4966)23-41-49
- (4942)77-07-48
- (861)203-40-90
- (391)204-63-61
- (3522)50-90-47
- (4712)77-13-04
- (4742)52-20-81
- (3519)55-03-13
- (375)257-127-884
- (495)268-04-70
- (8152)59-64-93
- (8552)20-53-41
- (831)429-08-12
- (3843)20-46-81
- (383)227-86-73
- (3496)41-32-12
- (3812)21-46-40
- (4862)44-53-42
- (3532)37-68-04
- (8412)22-31-16
- (342)205-81-47
- (8142)55-98-37
- (8112)59-10-37
- (863)308-18-15
- (4912)46-61-64
- (812)309-46-40
- (846)206-03-16
- (8342)22-96-24
- (845)249-38-78
- (8692)22-31-93
- (3652)67-13-56
- (4812)29-41-54
- (862)225-72-31
- (8652)20-65-13
- (3462)77-98-35
- (8212)25-95-17
- (4752)50-40-97
- (998)71-205-18-59
- (8482)63-91-07
- (3822)98-41-53
- (4872)33-79-87
- (4822)63-31-35
- (3452)66-21-18
- (347)229-48-12
- (3012)59-97-51
- (8422)24-23-59
- (8672)28-90-48
- (4922)49-43-18
- (423)249-28-31
- (844)278-03-48
- (8172)26-41-59
- (473)204-51-73
- (4112)23-90-97
- (4852)69-52-93
- (343)384-55-89